Schulz V-Series 580VV20X-3 5-HP 80-Gallon Two-Stage Air Compressor
【Schulz of America】 Schulz V-Series 580VV20X-3 5-HP 80-Gallon Two-Stage Air Compressor For Your Consideration Air Compressor。
Pairs Well With
30-Day Price Guarantee
30-Day Price Guarantee
- Free 30-Day Returns
- Ships from our US warehouse (delivered in 3–7 days)
- Found a lower price? Let us know and we will match it!
1-Year + 180-Day Warranty
1-Year + 180-Day Warranty
So that you can buy with confidence, we provide a comprehensive warranty on every product.
- Warranty Period: This product comes with a 12-month standard warranty.
- Extended Warranty: Buy from our official website and you can register directly for the extended warranty, adding a further 180 days of coverage.
For more details, see the [Warranty Policy].
After your purchase, be sure to complete [Product Registration] to activate your warranty.
Free shipping
Free shipping
- Free Shipping:
All orders ship free of charge and usually arrive within 7 days. - 30-Day Return Guarantee:
If you are not satisfied, you may return or exchange the item within 30 days of delivery. - Shipping Protection (recommended):
For extra peace of mind, we recommend adding Seel Shipping Protection at checkout. With this coverage you can file a claim directly for shipping delays, loss or damage, and receive faster handling and stronger protection.
Please note that if shipping protection is not added, compensation is handled according to the carrier's rules and the applicable conditions. We are always happy to help with logistics inquiries, but the scope of compensation follows the carrier's policy.
For full details, please see the [Shipping Policy] and [Return Policy] pages.
Sign up and be the first to know when it lands
Features
Features
Specifications
Specifications
| Product Specifications | Value |
|---|---|
| Schulz V-Series 580VV20X-3 5-HP 80-Gallon Two-Stage Air Compressor | |
| Model Number | 8573069426823 |
| Age Range | 5+ |
| Shipping | Free shipping |
| Delivery Time | 1–5 days |
Reviews (252)
Reviews (252)
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details, nor do we have access to your credit card information.
Schulz 580VV20X-3: 650 lbs of cast iron and steel, with an after-cooler fitted
Two things separate this machine from the rest of the Schulz V-Series shelf. It weighs 650 lbs, which is the most metal of any 80-gallon unit in this group, and its specification sheet lists an after-cooler as standard — a line that reads No on almost every sibling model. It is a three-phase, 5 HP, two-stage machine rated to 175 PSI on an upright 80-gallon ASME receiver.
Before the features, one thing to settle, because it affects how you plan the install.
Two figures to settle before you plan the install
Published figures for this model differ on two points. Both sets are below, each attributed to its source.
| Figure | Schulz structured spec sheet | Specification fields on this listing |
|---|---|---|
| Length | 48 inches | 31.5 inches |
| Width | 42 inches | 25.2 inches |
| Height | 81 inches | 78 inches |
| Voltage | 460 Volt AC | 208-230/460V |
The dimension gap is large enough to matter: one set describes a machine that fits a narrow alcove, the other a noticeably wider crate. The voltage difference is the difference between a motor that can be configured for a lower supply and one that needs 460V, which changes whether a transformer appears on your electrician's quote.
Two things you can do about it. For space, plan against the larger figures: a bay that accommodates the bigger set accommodates either, so you cannot be caught out. For voltage, confirm the motor's nameplate rating with us in writing before you order and we will take it straight from Schulz. Both sources agree it is a three-phase machine and both list 460V; what differs is whether anything lower is available.
650 lbs is a specification, not a shipping inconvenience
Weight is the number buyers skip, and on a compressor it is a telling one. A reciprocating pump is a machine trying to shake itself apart several times a second: pistons reversing, valves slamming, a crankshaft loaded and unloaded every revolution. Mass absorbs that. A heavy cast iron block on a substantial base turns vibration into heat and noise instead of fatigue at the mounts, the fittings and the tank welds.
Iron does a second job at once. It conducts heat far better than the aluminium used in lighter pumps, so it pulls heat out of the cylinder walls and hands it to the fins rather than holding it where the oil film lives. Cooler oil keeps its film strength and does not varnish the rings. Nearly everything that kills a compressor pump traces back to heat, and mass is one way this one refuses to hold on to it. The cost is delivery day — see shipping, below.
The after-cooler earns its keep downstream
Air leaves a two-stage pump hot and carrying water vapour. Where the after-cooler changes things is not really inside the compressor — it is everywhere after it.
By dropping discharge temperature before the air reaches the tank, it causes a large share of that moisture to condense at the receiver, where the drain is, instead of travelling into your pipework as hot wet air and condensing wherever the line happens to be coolest. That matters because the things downstream are the things you care about: filter elements that load up with water, regulators that hunt, air tools rusting from the inside, and finish work ruined by a slug of water arriving at the gun in the middle of a panel.
Be clear about the limit. This is not a dryer — the sheet lists no air dryer, and if you need genuinely dry air for painting or instrumentation you still need one. An after-cooler makes that dryer's job smaller, and on a machine with no dryer at all it moves most of the water to the one point in the system designed to get rid of it.
Will It Fit?
- Floor and height: use the larger of the two published sets — 48 inches by 42 inches on plan and 81 inches tall — and you are safe whichever proves correct. Measure to the lowest obstruction above the intended position, not to the ceiling.
- Access: whichever set is right, leave room to reach the tank drain and the belt guard. A drain you cannot get to is a drain that never gets opened, and standing water is what corrodes a receiver from the inside.
- Weight: 650 lbs on an upright base is a concentrated load. Schulz publishes no minimum slab thickness or concrete rating for this model and we will not invent one; on a poured commercial floor it is routine, on a suspended floor it deserves a professional opinion first.
- Power: three phase — settle the voltage question above before any wiring is quoted. Amp draw and breaker size are not published; the recommended-breaker field says consult a certified electrician, which is the only defensible answer.
- Plumbing: a 1/2-inch tank outlet. Size the downstream run for the flow you intend to draw.
Confirming the space, the floor and the supply is the buyer's responsibility before ordering.
Perfect For
- Three-phase shops running long duty cycles, where mass, cast iron and an after-cooler all pay back over hours of running rather than minutes.
- Body and finishing work, where water in the line is not an annoyance but a re-do.
- Tight bays with height available, since the upright tank buys back floor area.
- Buyers replacing a light single-stage machine that has been short-cycling itself to death.
What Is Fitted
- WEG electric motor, 5 HP, three phase
- V-Series solid cast iron two-stage pump, belt driven
- After-cooler
- Magnetic starter, mounted and prewired
- Intake air filter
- Oversized main bearings and Swedish steel valves
- CNC-machined components
- Notched belts inside an enclosed belt guard
- Powder-coated components
- 80-gallon upright ASME air receiver with safety valve and a 1/2-inch outlet
- Pressure gauge and oil sight glass
Specifications
Motor and power
| Motor | 5 HP, WEG |
|---|---|
| Phase | Three phase |
| Voltage | Published figures differ - see the note above |
| Starter | Magnetic, mounted and prewired |
| Breaker | Consult a certified electrician |
Pump
| Type | Two-stage, belt drive |
|---|---|
| Material | Solid cast iron |
| Maximum pressure | 175 PSI |
| After-cooler | Yes |
| Air dryer | No |
| Lubrication | Oil lubricated, splash, sight glass |
Tank, size and weight
| Tank | 80-gallon, upright |
|---|---|
| Tank outlet | 1/2-inch |
| Dimensions | Published figures differ - see the note above |
| Weight | 650 lbs |
Certification, stated plainly
ASME is the certification recorded for this compressor, covering the air receiver and its safety valve. It is a pressure-vessel standard and it is the right one to demand on the component that stores the energy — a tank failure is the one failure mode on a compressor with no recovery.
The boundary is worth naming rather than blurring. It is not an electrical safety listing and it does not certify the assembled machine or its control gear. On a fixed three-phase installation that question gets asked more often, by insurers and by facilities standards. Ask us before ordering and we will confirm in writing what this unit carries.
Shipping and Delivery
Freight only, to the lower 48 states, quoted live at checkout against your delivery address rather than from a stale table.
This is the heavy one in the range, so plan the unload properly. At 650 lbs crated it is a forklift or a heavy-duty pallet jack on a solid surface — not a tail-lift-and-hope job, and not something a driver will move for you. If you have no dock or forklift, take terminal pickup and bring a trailer. Residential delivery is offered and carries a fee, shown at checkout. Walk the crate with the driver and write any damage onto the bill of lading before signing; a clean signature is very hard to reopen.
Collection from Acworth, GA is available for Schulz. Call, text or chat and we will confirm the crate size and the voltage question with you before you commit: 866-774-7743.
Warranty
Schulz covers this unit for 1 year and its pump for 2 years. Keep the invoice and note the date it entered service.
The usual and important caveat: leave the pump, motor and starter assembled until a claim is raised. A machine opened beforehand is normally treated as ineligible however sound the diagnosis was. Call us and we will start it with Schulz on your behalf.